G109010 (IDT), Class C
EN 50131-3, Grade 2, Class II
The DUO I/O module BUS-2/BUS-1 for flush mounting has the function to extend the MB-Secure or MB12/24/48/100/256 plus intrusion panel with control and power supply via the BUS.
The 4 detector group inputs with clearing function allow detectors with conventional connection technology to be integrated to the BUS system (e.g. contacts and passive glass breakage sensors).
In "5-Input module" operation mode there can be connected 2 contacts to the 4th input so that replacment of a 013130.xx is feasible with little effort.
In addition, the module has 2 semiconductor outputs for any switching and control functions (max. 30 V DC / 50 mA per output). The operating voltage used for the external consumers can be the voltage from the module or from an external power supply, depending on the application. With the universal BUS interface the module can be operated at every BUS-2 or BUS-1 - compatible panel. With the universal BUS interface the module can be operated at every BUS-2 or BUS-1 - compatible panel.
Higher switching capacities (up to 250 V AC / 8 A) are possible in connection with the DUO relay module (Item. no. 010121.17).
- Operation on BUS-2:
- Operation as DUO I/O module
- Operation as 5-input module (compatibility mode)
- Operation on BUS-1:
- Operation as detector group connection module, switching module or universal connection module, as desired
- 4 detector group inputs with clearing function
- Optional end-of-line resistors selectable from 4k to 14k
- 4 LEDs as detector group status display or with freely programmable function (depending on the operating mode). Externally visible or with individual cover as desired.
- 2 semiconductor outputs, open collector, LOW active
- The two outputs are activated in parallel to LEDs 1 and 2
- Freely programmable in operation as DUO I/O module
- Easy mounting in flush-mounted installation box or hollow-wall box d=60 mm (DIN, Austria and Switzerland)
- Combined operation with DUO relay module for high switching capacities
Rated operating voltage |
12 V DC |
Rated operating voltage range |
9 V to 15 V DC |
Current consumption at 12 V DC |
5 mA, 0.6 mA in addition per detector group, 1.3 mA in addition per LED |
Detector zone input |
with clear function, monitoring range 12k1 ±20% |
Semiconductor output |
max. 30 V DC, 50 mA, open collector, LOW active |
Type of protection EN 60529 |
IP40 |
Operating temperature range |
-5 °C bis + 45 °C |
Storage temperature range |
-25 °C bis + 70 °C |
Dimensions (ØxD) |
Module: 58 x 26 mm |
Dimensions (L x W x D) |
Frame: 70 x 70 x 1 mm |
With firmware V03.xx and operation mode "5-input module" the input 4 has to be equipped with 2 contacts 12k1 and 6k04.
Corresponding screw driver.
1 module cover frame.
4-hole-foil.