IDT, Class C VdS:G115010
This module allows connection of hardwired arming units over BUS-2 or BUS-1 to an intruder panelMB-Secure- or MB12/24/48/100/256 plus.
For this, block locks (conventional connection), keyswitches or door code devices or operating device can be connected.
Also included are inputs for bolt switching contact, opening contact, glass breakage sensor and an additional tamper input.
The spacious housing and the pluggable screw terminals allow a fast and cost effective installation.
- Operation on BUS-2 (MB24/48/100.10)
- Operation on BUS-1 (MB24/48/100.10/256/256plus)
- Connection of blocklock or keyswitch with arm/disarm and tamper
- 2 free detector group inputs, e.g. for bolt contact and magentic contact
- Pluggable screw terminals at all connections
- 2 open collector low active outputs
Rated operating voltage |
12 V DC |
Rated operating voltage range |
9 V ... 15 V DC |
Current consumption at 12 V DC |
5 mA, 0.6 mA in addition per detector group, 1,3 mA in addition per LED |
Detector zone input |
with clear function, monitoring range 12k1 ±20% |
LED - indicator |
1,3 mA |
Semiconductor output |
max. 30 V DC, 50 mA, open collector, LOW aktiv |
Type of protection EN 60529 |
IP30 |
Environmental class as per VdS |
II |
Operating temperature range |
-10 °C ... + 55 °C |
Storage temperature range |
-25 °C ... + 70 °C |
Dimensions (W x H x D) |
163 x 151 x 39 mm |
Colour |
white, similar to RAL 9016 |