The MB-Secure BUS-1 IB2 Converter allows operation of BUS-1 modules on a MB-Secure intrusion panel for cost-efficient upgrade of existing systems to MB-Secure while keeping most BUS-1 devices.
The connection to MB-Secure is established over IB2-BUS, allowing in-housing or field installation, programming is done via IQ PanelControl.
The two BUS-1 lines supporting in total 126 devices/addresses are euipped with self-resetting electronic fuses.
With the built-in BUS-1 testing function an easy and panel-independent testing of BUS-1 devices can be performed.
- 1 IB2-BUS line to MB-Secure, max. length 2000m
- 2 BUS-1 lines for 63 BUS-1 devices each, with max. 1000m cable length
- BUS-1 lines equipped with independent self-resetting electronic fuses
- Integrated BUS-1 testing device with LEDs
- Pluggable screw terminals
- Plastic case with cover and wall tamper contact
- Can be installed into panel housing or externally
- Supported BUS-1 devices:
- 1-/2 detector group module
- Operating unit
- Window sensor module
- Remote indicator module
- Internal siren module
- Logic detector
- Switching module
- Lock release module
- Standard detector
- Door module
- Door strike module
- Hold-up module
- Universal connector module
Rated operating voltage |
12 V DC |
Operating voltage range #4 |
10,5 V DC ... 15 VDC |
Current consumption at rated voltage |
30 mA |
Current drain external load |
pro BUS-1 Strang max. 1 A |
Type of protection EN 60529 |
IP 30 |
Environmental class as per VdS |
II |
Operating temperature range |
-5 °C ... +45 °C |
Storage temperature |
-25 °C ... +70 °C |
Dimensions PCB |
121 x 90 mm |
Dimensions housing (L x B x H) |
163 x 151 x 39 mm |
Colour of housing |
grey white (similar RAL 9002) |
MB-Secure BUS-1 IB2 converter in housing