G114020, Class C
EN50131-3:2010-02, Grade 3, Class II
SES-EMA-RL-T2:2010-08
Control unit for operation on MB-Secure with a low installation depth of only 2 cm. Each button/LED can be programmed with individual functions. Mounting and installation possible with mounting accessories included in the scope of delivery.
Combinations of one LED / LCD operating unit with one or more LED operating units are possible; in this case, the displays of the LCD refer to all connected LEDs / buttons.
Language-neutral design, i.e. all texts shown in the display come from the corresponding central programming. Labelling strips can be replaced during operation.
A reader for IK2/proX1 and IK3/proX2 data carriers is integrated in each operating unit for operating authorisation. By installing a corresponding additional board, mifare DESFire EV1 or LEGIC prime readers can be retrofitted.
ATTENTION: The transmission range may be shorter on metallic mounting surfaces.
- Modular design
- Several keypads to be combined horizontally and/or vertically
- Combinations with the operating unit
- f. m., s. m. and hollow wall mounting possible
- LED keypad with 20 freely programmable keys and individual labelling stripes
- LED / LCD keypad with 15 freely programmable keys and individual labelling stripes
- Labelling stripes exchangable during operation
- Key backlight with adjustable brightness
- Per key 1 duo LED red/yellow and 1 LED green, each of them with adjustable brightness
- LCD display provides additional information on the status of the system as well as of required operation actions
- LCD backlight with adjustable brightness
- Software supported settings for labelling stripes
- Integrated proX reader, replacable through mifare DESFire or LEGIC advant
Rated operating voltage U_b |
12 V DC |
Quiescent current at 12V DC |
< 20 mA |
Time-limited write/read mode |
< 15 mA |
LED status display |
0 to 28 mA max., depending on brightness (max. 30 LEDs) |
Button Luminous background |
0 to 16 mA max., depending on brightness |
LCD Luminous background |
0 to 19 mA max., depending on brightness |
Maximum current consumption |
98 mA |
Type of protection EN 60529 |
IP40 |
Environmental class as per VdS |
II |
Operating temperature range |
-5 °C to +45 °C |
Storage temperature range |
-25 °C to +70 °C |
Dimensions (W x H x D) |
218 x 162 x 20 mm |
Colour |
traffic white (similar to RAL 9016), optional basalt grey (similar to RAL 7012) or optional traffic black (similar to RAL 9017) |