G114026, class C
EN50131-3, Grad 3, Class II
SES-EMA-RL-T2:2010-08
Expander module with housing for MB-Secure with two detector group inputs and four free programmable outputs and for connection of acoustic siganalling devices and flashers.
The module can be installed within the panel housing or decentralized near to the corresponding alarm device. Control and supervision is done via BUS-2.
Available connectitvity:
Honeywell:
Compact alarming device 048720.17 (flasher with acoustic signalling device) and additional acoustic signalling device 048700.17.
Compact signalling device 160455.10:
(Flasher with acoustic signalling device) and additional acoustic signalling device 160456.10. With this configuration it will be distinguished between intruder/hold-up alarm, fire alarm and technique alarm.
- Operation on BUS-2
- 2 freely programmable analogue inputs, with reset function, e.g. for tamper output
- Up to 4 freely programmable outputs (active high) when using 048720.17
- Easy mounting on the bottom of the panel housing or in a separate box
- Cover tamper
- Pry-off tamper
Rated operating voltage |
12 V DC |
- inactive / detector zone open, LEDs off |
55 mA |
- active with Honeywell 048700.17 / 048720.17 |
max 1 A |
- active with ESSER 160455.10 / 160456.10 |
max. 1.1 A |
- analog outputs A1 ... A4, high activ |
500 mA |
Type of protection EN 60529 |
IP30 |
Environmental class as per VdS |
II |
Operating temperature range |
-5 °C to +45 °C |
Storage temperature |
-25 °C to +70 °C |
Dimensions PCB |
121 x 90 mm |
Colour of housing |