Operation on BUS-2 or alternatively on BUS-1.
Approvals: G108509 (IDT), class B
G108510 (IDT), class B, retrofitted for vertical curtain optics
G108511 (IDT), class B, retrofitted for long range optics
According: EN 50131-2-2 (08/09), grade 2 environmental class II
SES-EMA-RL-T2:2010-08
The Viewguard PIR detectors are motion detectors that work by the passive infrared principle.
For continuous detection, the detector are equipped with a high-quality mirror optics. The standard models are delivered with a mirror for surface optics. Upon request the detectors can be upgraded on-site to route or curtain optics by integrating separately available accessories.
The detectors are suitable for intrusion detection control panels equipped with BUS-2 or BUS-1 technology or conventional connection technology and are available with or without anti-mask (AM) monitoring.
- Approvals / Conformity
- Viewguard PIR AM BUS-2/BUS-1 or FAI: VdS Class C (G108036/G108037/G108038 or G107087 EN 50131-1 and EN 50131-2-2: 2008-09, Grade 3
- Viewguard PIR BUS-2/BUS-1 or FAI: VdS Class B (G108509/G108510/G108511 or G107509) EN 50131-1 and EN 50131-2-2: 2008-09, Grade 2
- Anti-mask monitoring AM (AM detectors only)
- Detects covering and spraying of the window, range up to 30 cm
- LED display
- Unambiguous display of the operating state and detection display in the walk test mode via two LEDs
- FAI-logic (first alarm indication, only BUS-2 on 561-MB24/48/100 and FAI detectors)
- The detector triggered first can be identified by means of the LED display
- Walk test function
- Easy method of performing a functional control and a detection range check
- Detector group input (BUS detectors only) for integrating contacts/potential-free detectors into the BUS-2 system (on 561-MB24/48/100 control panels) or BUS-1 system (on 561-MB24/48/100 and MB256 plus control panels) the detector group is not clearable
- Range of detection
- Range programmable in four steps
- Sensitivity of detection
- Sensitivity programmable in two steps
- Storing / not storing fault/covering (AM detectors only)
- Storing: Message is stored until it is cleared
- Not storing: Message is reset automatically once the fault/covering has been eliminated
- Self-test (AM detectors only)
- Cyclic detector test for correct functioning
- Operating voltage monitoring
- Fault signal when operating voltage is too low
- Temperature measurement (BUS-2 on 561-MB12/24/48/100 only)
- Temperature alarm when ambient temperature is inadmissibly high/low
- Alarm thresholds programmable
- Tear-off protection / cover contact
- For mounting according to EN 50131-2-2 Grade 3
- Versatile mounting options (see figure)
- Inclined vertically downward, horizontally toward the left or right, corner mounting and mounting on adjusting hinge or ball joint (accessories)
Rated operating voltage |
12 V DC |
Current consumption at 12 V DC |
0.6 mA BUS-2 / 3 mA BUS-1 / 4 mA LED |
Range |
programmable |
Volumetric optics |
22 zones, up to 15 m, opening angle 80° |
Installation position |
vertical, optics down |
Pan Travel |
Detector with adjustable hinge: ±20° horizontal; +4° to -8° vertical |
Alarm display |
LED red |
Fault display |
LED yellow |
Type of protection EN 60529 |
IP30 |
Environmental class as per VdS |
II |
Operating temperature range |
-10 °C to +55 °C |
Storage temperature range |
-25 °C to +70 °C |
Dimensions without adjustable hinge (W x H x D) |
64 x 130 x 48 mm |
Colour |
traffic white, similar to RAL 9016 |
Conformity to guidelines |
EN 50131-1 and EN 50131-2-2: 2008-09, grade 2 |
033434 Viewguard PIR set of mirrors, curtain optics (3 per packaging unit)
033435 Viewguard PIR set of mirrors, route optics (3 per packaging unit)
033390.17 Adjusting joint, horizontal ±20°, vertical +4° to -8°, according to EN Grade 2
033588.17 Ball joint set for wall and corner mounting, horizontal ±45°, vertical ±20° not according to VdS and EN
033391.17 Seal, (20 per packaging unit)