G100067 (IDT), Class C
Its compact and timeless design, combined with its high signal effect and mounting flexibility, makes this combined alarm device suitable for universal use. Provided with sabotage contact, reach-through protection and tear-off protection, connection module with monitoring circuit for the integrated loudspeaker and the flashing lamp.
Rated operating voltage |
12 V DC |
Rated operating voltage range |
10 V to 15 V DC |
Current consumption beacon at UNENN |
< 400 mA |
Current consumptionat Pressure chamber loudspeaker at UNENN |
typ. 250 mA |
Frequency of flash |
ca. 2 Hz |
Loudness level |
>100 dB(A) |
Environmental class as per VdS |
IV |
Type of protection EN 60529 |
IP44 |
Operating temperature range |
-25 °C to +60 °C |
Storage temperature range |
-25 °C to +70 °C |
Dimensions (W x H x D) |
185 x 315 x 98 mm |
Colour |
traffic-white, similar to RAL 9016 |
For use with intrusion detection control panels of the HB/MB series.