G195078 (IDT), Class C
Impact-resistant plastic housing with sheet metal lining. Activation is effected by applying the operating voltage.
Operating voltage |
12 V DC resp. 24 V DC |
Voltage range |
10.2 - 13.8 V DC resp. 20.4 to 27.6 V DC |
Current consumption |
alarm signal ca. 330 mA (12 V), 200 mA (24 V); alarm signal fire ca. 370 mA (12 V), 210 mA (24 V); technical alarm signal ca. 200 mA (12 V), ca. 110 mA (24 V) |
Frequency |
alarm signal ca. 400 - 1200 Hz (increasing 1.6 sec.); alarm signal fire ca. 1200 - 500 Hz (falling 1.0 sec.); technical alarm signal ca. 820 Hz (on: 0.75 sec./off: 0.75 sec.) |
Signal flashing lamp |
ca. 200 mA (12 V); ca. 135 mA (24 V) |
Frequency of flash |
ca. 1 Hz (12 V); ca. 1.2 Hz (24 V) |
Loudness level |
100 dB(A)/1 m |
Sound pressure |
105 dB(A) |
Environmental class as per VdS |
IV |
Type of protection EN 60529 |
IP34 |
Material |
plastic |
Weight |
1.2 kg |
Dimensions (W x H x D) |
200 x 110 x 65 mm |
Colour |
grey-white, similar to RAL 9002 |
Monitoring resistance 4.7 kOhm and 10 kOhm integrated.
Must be controlled via a relay.
No monitoring of pressure chamber loudspeaker.